Mobile search icon
Environment Testing >> Locations >> Eurofins Environment Testing Air Toxics

Eurofins Environment Testing Air Toxics

Phone: 800-985-5955

AirToxics.Inquiries@et.eurofinsus.com

Check out our Unit Conversion Calculator

Eurofins Air Toxics was formed in 1989 for the purpose of providing analytical services relating to the determination of toxic air pollutants. Today, Eurofins Air Toxics is the global leader in air testing and Center of Excellence for Eurofins Environment Testing US in supporting a wide range of matrices for both routine and specialty air testing programs. Capabilities extend from trace level measurements required for indoor air testing to identifying and quantifying organics in complex matrices following EPA, ASTM and in-house developed methods.

 

Air Sampling Media & Instrumentation

With over 8,000 canisters, 5,000 quick-connect flow controllers and several thousand sorbent tubes, Eurofins Air Toxics maintains the largest single location air sampling media inventory of any laboratory in the United States. Analysis is supported with state-of-the-art instrumentation and equipment, which has been optimized in order to enhance performance and reliability. In addition, our expert staff has designed and built innovative equipment to address laboratory processing challenges and meet unique project needs. The investment in instrumentation means that Eurofins Air Toxics has the redundancy and capacity to effectively process a large number of samples and achieve the required report delivery timelines.

 

Analytical Capabilities

Eurofins Air Toxics supports numerous EPA methods described in the Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, commonly referred to as the “TO” methods. Additionally, the laboratory has implemented various ASTM methods. The following analyses are currently performed routinely at Eurofins Air Toxics. Special project requirements, including method developing, may be accommodated upon request.

Method

Analysis

Media

EPA TO-3

TPH by GC/ FID

Canister or Tedlar Bag

EPA TO-12

Non-methane Organic Compounds by GC/FID

Canister or Tedlar Bag

EPA TO-13A

Polynuclear Aromatic Hydrocarbons (PAHs) by GC/MS

PUF/XAD cartridge

EPA TO-15

Volatile Organic Compounds (VOCs) by GC/MS SIM/scan

Canister or Tedlar Bag

EPA TO-17

VOCs and SVOCs by TD-GC/MS

Sorbent Tubes

Method

Analysis

Media

ASTM D1945

C1-C5 Hydrocarbons and atmospheric gases GC/FID/TCD

Canister or Tedlar Bag

ASTM D1946

Atmospheric gases, ethane and ethane by GC/FID/TCD

Canister or Tedlar Bag

Method

Analysis

Media

EPA 325B

Benzene and VOCs by TD-GC/MS

Sorbent Tube

Mod TO-17

VOCs by TD-GC/MS

Radiello® 145

Mod TO-17

VOCs by Solvent Extraction GC/MS

Radiello® 130, WMSTM

Method

Analysis

Media

40 CFR Part 50 App J

Particulates (PM10 and TSP)

Filter

Experience

Eurofins Air Toxics provides services to the environmental engineering community, private industry and government sectors, providing both routine and specialty analyses. We partner with our clients, providing technical support during the project definition phase, educational resources on the use of sampling equipment and method options, operational support for media delivery, sample analysis, report delivery and technical support regarding data questions.

Eurofins Air Toxics has extensive Department of Defense (DoD) experience under DFARS compliance, as well contracting directly with the Army Corps of Engineers, Air Force Center for Environmental Excellence (AFCEE) and the U.S. Navy. The laboratory maintains DoD-ELAP accreditation for many of our commonly requested methods and analytes, and adheres to the most current DoD/DOE Quality Systems Manual (DoD/DOE QSM V5.4) providing the required quality parameters and specific data deliverables at a competitive price.

Eurofins Air Toxics supports the following types of projects utilizing active and passive sampling technologies:

  • Vapor Intrusion Investigations
  • Soil Gas Survey
  • Ambient/Fence-line Air Monitoring Programs including Method 325B for Refineries and Chemical Plants
  • Manufactured Gas Plant (MGP) Remediation Projects
  • Indoor Air Quality Assessments
  • Specialty Analysis Parameters Including ethylene oxide, 1,4-dioxane and extended hydrocarbon speciation

Areas of Expertise: Air and Vapor, PFAS Testing

Please enter this field. Maximum character limit is 100.
Please enter this field. Maximum character limit is 100.
Please enter this field. Maximum character limit is 100.
Please enter this field. Maximum character limit is 100.
Please enter this field. Maximum character limit is 100.
Please enter this field. Enter valid Phone Number with format (xxx-xxx-xxxx or 123-456-7890) Phone number cannot exceed more than 20 digits.
Please enter this field. Enter a valid Email Address.
Please enter this field. Maximum allowed characters is 250.
Allowed file size for upload is 2 MB. Allowed file types : doc,docx & pdf.
Please accept the privacy policy .

Input Captcha field.
Something went wrong. Please try again later. Invalid text in the fields.
Thank you for your submission